O2 Analyzer

Zirconia analyzers that measure trace oxygen in nitrogen — from ppm to percent — so diffusion and other inert-gas processes stay free of unwanted oxide.

O2 analyzer with zirconia sensor
ModelNGK SH-200
SV12.4 ppm O₂
Range0–100 ppm ~ 0–50 %
Accuracy±1 %FS repeat.

Overview · Diffusion

Trace oxygen, measured in real time

In the diffusion process, wafers are heated in a nitrogen atmosphere. A few ppm of oxygen is enough to grow unwanted oxide, so the O2 concentration in the N2 is monitored continuously.

An O2 analyzer draws a sample of the process gas across a heated zirconia sensor and reports the concentration from ppm levels up to percent, with analog outputs and alarms for the tool or the facility monitoring system.

Process
Diffusion · N2 purge
Measures
O2 concentration in N2
Range
0–10 ppm ~ 0–100 %
Repeatability
±1 % F.S.

How it works

Zirconia ceramic becomes an oxygen-ion conductor when heated — the basis of a fast, stable measurement down to ppm levels.

  1. 01

    Sample

    A pump or ejector draws process gas through the analyzer at a steady flow — 0.5 L/min on the TF series.

  2. 02

    Sense

    A heated zirconia element conducts oxygen ions. The analyzer turns the oxygen partial-pressure difference, or the ion-pumping current, into O2 concentration.

  3. 03

    Report

    Readings go to the display, a 4–20 mA or voltage output and RS-232C, with upper and lower concentration alarms.

  4. 04

    Calibrate

    Air-point calibration keeps readings accurate; low ppm ranges also use a standard calibration gas.

Applications

Wherever a process depends on an oxygen-free atmosphere.

Models

NGK SH-200 and TF series specifications. Tell us your gas, range and output and we’ll help you choose.

NGK seriesSH-200 Series
ItemSH-201-ASH-201-BSH-201-C
Sampling systemEjector suction systemPump suction systemPump suction system
Setting range0–500 ppm ~ 0–50 %0–1000 ppm ~ 0–20 %0–100 ppm ~ 0–25 %
Calibration functionAir 1-point calibration (standard gas calibration is required for the 0–100 ppm range)Air 1-point calibration (standard gas not required)Air 1-point calibration (standard gas calibration is required for the 0–100 ppm range)
Linearity±2 %FS
Repeatability±1 %FS
Drift±2 %FS / week
Response timeWithin 30 s
Warm-up time3 min
Power voltage100 V AC200 V AC100 V AC
NGK seriesTF Series
ItemTF-21D201TF-30D201
SensorTF-21D201TF-30
ReceiverDFT-201
Measurement principleZirconia concentration cell systemZirconia 2-cell pump critical current system
Measuring rangesMin. 0–10 ppm ~ max. 0–100 % 4 freely selected ranges (zero point fixed)Min. 0–10 ppm ~ max. 0–100 % 4 freely selected ranges Note: cannot measure 25 % O2 or greater
Scope of measurement0 – Air
CalibrationAir point calibration, max. 4 pointsAir point + max. 3-point calibration by calibration gas Air 1-point calibration (0–1000 ppm or greater) Calibration by data input (0–1000 ppm or greater, when the sensor is exchanged)
Output1 point 4–20 mA (non-isolated, load resistance < 600 Ω) 1 point 0–1 V, 0–5 V or 0–10 V (non-isolated)1 point 4–20 mA (non-isolated, load resistance < 600 Ω) 1 point 0–1 V, 0–5 V or 0–10 V (non-isolated)
Sample / calibration gas flow0.5 ± 0.02 L/min0.5 ± 0.1 L/min
Reproducibility±1 % F.S.±1 % F.S. (0–25 % fixed range: ±0.5 % F.S.)
LinearityOver 0–100 ppm: ±2 % F.S. Under 0–100 ppm: ±3 % F.S.±2 % F.S. (0–25 % fixed range: ±1.0 % F.S.)
Response time (90 %, calibration gas switching)0–1 % or greater: < 10 s Under 0–1 %: < 30 sOver 0–1000 ppm: < 30 s Under 0–1000 ppm: < 60 s
DriftLess than ±2 % F.S. / week
Power supplyAC 85–132 V (option: AC 170–264 V, DC 24 V ±10 %)
Contact input (no-voltage)Range switch input
Contact output (open collector, DC 25 V, max. 50 mA, NO/NC switchable)Analyzer abnormality · range echo back (2 or 3 range identification) · ready · concentration upper / lower limit alarm (0.0–9990.0 ppm or 0.0–100.0 %) Any 4 of the above can be assigned; settings can be changed
Range switchingLocal / remote / auto range switching (selectable)
First-order lag setting0–99 s
Output hold settingOff, a set value, or the value 5 s before an abnormality During warm-up, HOLD applies if there is a sensor or receiver abnormality
Concentration limit alarmsUpper and lower limits: 0.0–9990.0 ppm or 0.0–100.0 %
RS232C communicationTransmits measurement state, error code, measurement range and value Cable: straight cable

Repair & calibration

Serviced by technicians trained by NGK

CJ Tech is a service agent of NGK, the Japanese manufacturer, and repairs and calibrates SH-200 and TF series analyzers.

Other products

Service & custom units

Need to monitor O2 in your process?

Tell us the gas, the range and the tool. We’ll recommend a model or arrange repair and calibration.