O2 Analyzer

Authorized service agent of NGK (Japan) for O2 analyzer repair and calibration.

NGK O2 analyzer with sensor

Service agent of NGK · Japan

Repair and calibration for NGK O2 analyzers

We provide full repair service for O2 analyzers. The O2 analyzer is used in the Diffusion process of semiconductor plants to measure the concentration of O2 within N2 and prevent the formation of oxide during the process.

We are currently a service agent of NGK, a producer of O2 analyzers in Japan. CJ Tech is fully trained by NGK to provide repair and calibration services.

Process
Diffusion
Measures
O2 concentration in N2
Service
Repair & calibration
Series
SH-200 · TF

Serviced models

NGK SH-200 and TF series specifications for the analyzers we repair and calibrate.

NGK seriesSH-200 Series
ItemSH-201-ASH-201-BSH-201-C
Sampling systemEjector suction systemPump suction systemPump suction system
Setting range0–500 ppm ~ 0–50 %0–1000 ppm ~ 0–20 %0–100 ppm ~ 0–25 %
Calibration functionAir 1-point calibration (standard gas calibration is required for the 0–100 ppm range)Air 1-point calibration (standard gas not required)Air 1-point calibration (standard gas calibration is required for the 0–100 ppm range)
Linearity±2 %FS
Repeatability±1 %FS
Drift±2 %FS / week
Response timeWithin 30 s
Warm-up time3 min
Power voltage100 V AC200 V AC100 V AC
NGK seriesTF Series
ItemTF-21D201TF-30D201
SensorTF-21D201TF-30
ReceiverDFT-201
Measurement principleZirconia concentration cell systemZirconia 2-cell pump critical current system
Measuring rangesMin. 0–10 ppm ~ max. 0–100 % 4 freely selected ranges (zero point fixed)Min. 0–10 ppm ~ max. 0–100 % 4 freely selected ranges Note: cannot measure 25 % O2 or greater
Scope of measurement0 – Air
CalibrationAir point calibration, max. 4 pointsAir point + max. 3-point calibration by calibration gas Air 1-point calibration (0–1000 ppm or greater) Calibration by data input (0–1000 ppm or greater, when the sensor is exchanged)
Output1 point 4–20 mA (non-isolated, load resistance < 600 Ω) 1 point 0–1 V, 0–5 V or 0–10 V (non-isolated)1 point 4–20 mA (non-isolated, load resistance < 600 Ω) 1 point 0–1 V, 0–5 V or 0–10 V (non-isolated)
Sample / calibration gas flow0.5 ± 0.02 L/min0.5 ± 0.1 L/min
Reproducibility±1 % F.S.±1 % F.S. (0–25 % fixed range: ±0.5 % F.S.)
LinearityOver 0–100 ppm: ±2 % F.S. Under 0–100 ppm: ±3 % F.S.±2 % F.S. (0–25 % fixed range: ±1.0 % F.S.)
Response time (90 %, calibration gas switching)0–1 % or greater: < 10 s Under 0–1 %: < 30 sOver 0–1000 ppm: < 30 s Under 0–1000 ppm: < 60 s
DriftLess than ±2 % F.S. / week
Power supplyAC 85–132 V (option: AC 170–264 V, DC 24 V ±10 %)
Contact input (no-voltage)Range switch input
Contact output (open collector, DC 25 V, max. 50 mA, NO/NC switchable)Analyzer abnormality · range echo back (2 or 3 range identification) · ready · concentration upper / lower limit alarm (0.0–9990.0 ppm or 0.0–100.0 %) Any 4 of the above can be assigned; settings can be changed
Range switchingLocal / remote / auto range switching (selectable)
First-order lag setting0–99 s
Output hold settingOff, a set value, or the value 5 s before an abnormality During warm-up, HOLD applies if there is a sensor or receiver abnormality
Concentration limit alarmsUpper and lower limits: 0.0–9990.0 ppm or 0.0–100.0 %
RS232C communicationTransmits measurement state, error code, measurement range and value Cable: straight cable

Certificate

Trained and certified by NGK

CJ Tech received full training on NGK O2 analyzers to provide repair and calibration services. Select the certificate to enlarge it.

Service & custom units

Analyzer drifting or out of calibration?

Send the model and the symptom. We’ll review it and schedule repair or calibration.